Power Transformer Manufacturing 5 MVA

ISO 9001:2015 certified manufacturer of power transformers from 5 MVA, built to IS standards for maximum reliability and operational efficiency.

5 MVA Distribution Transformer — Shri Ram Transformer
How it works

Stepping high voltage down to usable power

Designed for high-capacity power distribution in industrial plants, utility substations, and infrastructure projects, the transformer steps medium-voltage electricity down to a safe, stable low voltage — using electromagnetic induction between three-phase primary and secondary windings, with no moving parts.

HV INPUT → CORE & WINDINGS → LV OUTPUT
High voltage (input) Winding / core Low voltage (output)

The primary (HV) winding has many turns of fine wire; the secondary (LV) winding has fewer turns of thicker wire. Electrical energy crosses between them magnetically through the CRGO core — the ratio of turns sets the ratio of voltages, with the two circuits fully isolated from each other.


Built for the field

What goes into every unit

Each transformer is engineered for superior efficiency, high mechanical and short-circuit strength, and long, minimal-maintenance operation under demanding industrial and utility conditions.

High-Efficiency CRGO Core

Cold Rolled Grain Oriented silicon steel keeps no-load and load losses low while improving magnetic performance.

Premium Copper or Aluminium Winding

Precision-engineered electrolytic-grade copper or high-conductivity aluminium windings, both built for long service life.

Heavy-Duty Fabricated Tank

Corrosion-resistant outdoor construction built for high mechanical and short-circuit strength.

ONAN Cooling with ONAF Option

Standard Oil Natural Air Natural cooling, with Oil Natural Air Forced available for higher thermal loads.

Excellent Voltage Regulation

Holds a consistent output voltage through load fluctuations, protecting connected equipment.

Long Service Life

Minimal-maintenance design, routine tested per IS 2026 before dispatch.


Nameplate data

Technical specifications

Standard configuration below — voltage ratio, tap changer, vector group, and winding material can be customized to your project.

Shri Ram Transformer — Type DT-5000
Rating5 MVA (5000 kVA)
PhaseThree Phase
Frequency50 Hz
CoolingONAN / ONAF (Optional)
Core MaterialCRGO Silicon Steel
WindingCopper / Aluminium
InsulationOil Immersed
InstallationOutdoor
StandardIS 1180 / IS 2026
Tap ChangerOCTC / OLTC (Optional)
Primary Voltage11 / 22 / 33 kV
Secondary Voltage433 V or As Required
Vector GroupDyn11
ImpedanceAs Per IS Standards

Where it's installed

Applications

Sized for high-capacity industrial, utility, and infrastructure loads where reliable, large-scale power distribution matters most.

Power Distribution Utilities
Industrial Manufacturing Plants
Steel & Cement Industries
Commercial Complexes
Hospitals
Data Centers
Renewable Energy Projects
Infrastructure Developments
Mining Operations
Large Residential Townships

From design to dispatch

Manufacturing process

Every unit moves through the same monitored sequence, start to finish.

01

Design & Engineering

Specifications finalized against project requirements.

02

CRGO Core Cutting & Assembly

CRGO steel cut and assembled to spec.

03

Precision Coil Winding

Primary and secondary windings precision-formed and insulated.

04

Tank Fabrication & Core-Coil Assembly

Heavy-duty fabricated steel tank built and core-coil assembly fitted.

05

Vacuum Drying & Oil Filling

Assembly dried under vacuum, then filled with insulating oil.

06

Routine Testing & Quality Inspection

Full IS 2026 test sequence and final quality inspection.

07

Final Packing & Dispatch

Secure packaging and dispatch with test documentation.


Quality assurance

Every unit is tested before it leaves the factory

Insulation Resistance Test
Turns Ratio Test
Winding Resistance Test
No Load Loss Test
Load Loss Test
High Voltage Test
Induced Voltage Test
Oil BDV Test
Polarity Test
Leakage Test
Temperature Rise Test (If Required)
Routine Tests as per IS 2026

Only transformers that pass every inspection are cleared for dispatch, with complete routine test reports supplied alongside each unit.


Common questions

FAQ

What is a 5 MVA transformer used for? +
A 5 MVA transformer is used for supplying reliable electrical power to large industrial facilities, utility substations, commercial complexes, infrastructure projects, and renewable energy plants.
Is copper winding available? +
Yes — both copper and aluminium winding options are available based on project requirements.
Which cooling system is used? +
The standard configuration uses ONAN (Oil Natural Air Natural) cooling, while ONAF (Oil Natural Air Forced) is available for higher cooling requirements.
Can the transformer be customized? +
Yes — voltage ratio, impedance, vector group, winding material, cooling method, and tap changer options can all be customized according to customer specifications.
Which standards does it comply with? +
The transformer is manufactured and tested in accordance with IS 1180 and IS 2026 standards.
Do you provide routine test reports? +
Yes — every 5 MVA Distribution Transformer is supplied with complete routine test reports before dispatch to ensure quality, safety, and reliable performance.

Get Started Today

Powering Industries with Reliable Transformer Solutions
Get in touch with our experts for transformer manufacturing, customization, repair, testing, and installation services.

Have Additional Questions?

Need help choosing the right transformer for your project? Our team is here to assist you with technical guidance and quotations.

Call Us

+91 9756545365, +91 7830507022

Mail Us

srtsethi1@gmail.com