Power Transformer Manufacturing 1 MVA

ISO 9001:2015 certified manufacturer of power transformers from 1 MVA, built to IS standards for maximum reliability and operational efficiency.

1 MVA Distribution Transformer — Shri Ram Transformer
How it works

Stepping high voltage down to usable power

The transformer takes medium-voltage electricity from the grid and steps it down to a safe, stable low voltage for the point of use — using electromagnetic induction between three-phase primary and secondary windings, with no moving parts.

HV INPUT → CORE & WINDINGS → LV OUTPUT
High voltage (input) Winding / core Low voltage (output)

The primary (HV) winding has many turns of fine wire; the secondary (LV) winding has fewer turns of thicker wire. Electrical energy crosses between them magnetically through the CRGO core — the ratio of turns sets the ratio of voltages, with the two circuits fully isolated from each other.


Built for the field

What goes into every unit

Each transformer is engineered for low losses and long, low-maintenance operation under demanding industrial and utility conditions.

Premium CRGO Core

Cold Rolled Grain Oriented silicon steel keeps no-load and load losses low while improving magnetic performance.

Copper or Aluminium Winding

Choose electrolytic-grade copper or high-conductivity aluminium windings, both built for long service life.

Heavy-Duty Fabricated Tank

Corrosion-resistant, steel-fabricated tank built for continuous operation and high mechanical strength.

ONAN / ONAF Cooling

Standard Oil Natural Air Natural cooling, with Oil Natural Air Forced available for higher thermal loads.

Excellent Voltage Regulation

Holds a consistent output voltage through load fluctuations, protecting connected equipment.

Routine Tested to IS 2026

Every unit passes a full routine test sequence per IS 2026 before it's cleared for dispatch.


Nameplate data

Technical specifications

Standard configuration below — voltage ratio, tap changer, vector group, and winding material can be customized to your project.

Shri Ram Transformer — Type DT-1000
Rating1 MVA (1000 kVA)
PhaseThree Phase
Frequency50 Hz
CoolingONAN / ONAF (Optional)
Core MaterialCRGO Silicon Steel
WindingCopper / Aluminium
InsulationOil Immersed
InstallationOutdoor
StandardIS 1180 / IS 2026
Tap ChangerOCTC / OLTC (Optional)
Primary Voltage11 / 22 / 33 kV
Secondary Voltage433 V or As Required
Vector GroupDyn11
ImpedanceAs Per IS Standards

Where it's installed

Applications

Sized for large industrial, commercial, and utility loads where a stable, high-capacity supply matters most.

Industrial Plants
Commercial Complexes
Manufacturing Units
Hospitals
Data Centers
Educational Institutions
Residential Townships
Infrastructure Projects
Utility Power Distribution
Renewable Energy Projects

From design to dispatch

Manufacturing process

Every unit moves through the same monitored sequence, start to finish.

01

Design Engineering

Specifications finalized against project requirements.

02

CRGO Core Cutting & Assembly

CRGO steel cut and assembled to spec.

03

Coil Winding & Insulation

Primary and secondary windings formed and insulated.

04

Tank Fabrication & Assembly

Heavy-duty steel tank built and core-coil assembly fitted.

05

Vacuum Drying & Oil Filling

Assembly dried under vacuum, then filled with insulating oil.

06

Routine Testing & Final Inspection

Full IS 2026 test sequence and final quality inspection.

07

Packing & Dispatch

Secure packaging and dispatch with test documentation.


Quality assurance

Every unit is tested before it leaves the factory

Insulation Resistance Test
Turns Ratio Test
Winding Resistance Test
No Load Loss Test
Load Loss Test
High Voltage Test
Induced Voltage Test
Oil BDV Test
Polarity Test
Leakage Test
Temperature Rise Test (If Required)
Routine Tests as per IS 2026

Only transformers that pass every inspection are cleared for dispatch, with complete routine test reports supplied alongside each unit.


Common questions

FAQ

What is a 1 MVA transformer used for? +
It is used to distribute electrical power to large industrial plants, commercial buildings, utilities, hospitals, and infrastructure projects.
Can it be supplied with copper winding? +
Yes — both copper and aluminium winding options are available.
Which cooling system is used? +
The standard cooling method is ONAN, while ONAF is available for higher cooling requirements.
Can voltage ratings be customized? +
Yes — primary voltage, secondary voltage, impedance, vector group, and tap changer options can all be customized.
What standards does it comply with? +
The transformer is manufactured and tested according to IS 1180 and IS 2026 standards.
Do you provide test reports? +
Yes — every transformer is supplied with complete routine test reports before dispatch.

Get Started Today

Powering Industries with Reliable Transformer Solutions
Get in touch with our experts for transformer manufacturing, customization, repair, testing, and installation services.

Have Additional Questions?

Need help choosing the right transformer for your project? Our team is here to assist you with technical guidance and quotations.

Call Us

+91 9756545365, +91 7830507022

Mail Us

srtsethi1@gmail.com