Power Transformer Manufacturing 10 MVA

ISO 9001:2015 certified manufacturer of power transformers from 10 MVA, built to IS standards for maximum reliability and operational efficiency.

10 MVA Distribution Transformer — Shri Ram Transformer
How it works

Stepping high voltage down to usable power

Engineered for high-capacity power distribution in utility substations, heavy industries, and large commercial infrastructures, the transformer steps medium-voltage electricity down to a safe, stable low voltage — using electromagnetic induction between three-phase primary and secondary windings, with no moving parts.

HV INPUT → CORE & WINDINGS → LV OUTPUT
High voltage (input) Winding / core Low voltage (output)

The primary (HV) winding has many turns of fine wire; the secondary (LV) winding has fewer turns of thicker wire. Electrical energy crosses between them magnetically through the CRGO core — the ratio of turns sets the ratio of voltages, with the two circuits fully isolated from each other.


Built for the field

What goes into every unit

Each transformer is engineered for exceptional efficiency, high short-circuit withstand capability, and long, low-maintenance operation under continuous heavy-load conditions.

Premium CRGO Core

Cold Rolled Grain Oriented silicon steel keeps core and copper losses low while improving magnetic performance.

High-Conductivity Winding

Choose electrolytic-grade copper or high-conductivity aluminium windings, both built for long service life.

Heavy-Duty Fabricated Tank

Corrosion-resistant outdoor construction built for high short-circuit withstand capability.

ONAN Cooling with ONAF/OFAF Option

Standard Oil Natural Air Natural cooling, with ONAF and OFAF available for higher thermal loads.

Excellent Voltage Regulation

Holds a consistent output voltage through load fluctuations, protecting connected equipment.

Long Operational Life

Low maintenance requirements, routine tested per IS 2026 before dispatch.


Nameplate data

Technical specifications

Standard configuration below — voltage ratio, tap changer, vector group, and winding material can be customized to your project.

Shri Ram Transformer — Type DT-10000
Rating10 MVA (10000 kVA)
PhaseThree Phase
Frequency50 Hz
CoolingONAN / ONAF / OFAF (Optional)
Core MaterialCRGO Silicon Steel
WindingCopper / Aluminium
InsulationOil Immersed
InstallationOutdoor
StandardIS 1180 / IS 2026
Tap ChangerOLTC (Optional OCTC)
Primary Voltage11 / 22 / 33 kV
Secondary Voltage433 V or As Required
Vector GroupDyn11
ImpedanceAs Per IS Standards

Where it's installed

Applications

Sized for high-capacity utility, heavy-industrial, and infrastructure loads where continuous, large-scale power distribution matters most.

Utility Power Substations
Heavy Manufacturing Industries
Steel & Cement Plants
Oil & Gas Facilities
Renewable Energy Projects
Mining Operations
Metro Rail & Infrastructure Projects
Data Centers
Commercial Complexes
Large Industrial Parks

From design to dispatch

Manufacturing process

Every unit moves through the same monitored sequence, start to finish.

01

Engineering Design & Specification Approval

Specifications finalized and approved against project requirements.

02

CRGO Core Cutting & Core Assembly

CRGO steel cut and assembled to spec.

03

Precision Coil Winding & Insulation

Primary and secondary windings precision-formed and insulated.

04

Tank Fabrication & Core-Coil Assembly

Heavy-duty fabricated steel tank built and core-coil assembly fitted.

05

Vacuum Drying & Oil Filling

Assembly dried under vacuum, then filled with insulating oil.

06

Routine Testing & Quality Inspection

Full IS 2026 test sequence and final quality inspection.

07

Final Packing & Dispatch

Secure packaging and dispatch with test documentation.


Quality assurance

Every unit is tested before it leaves the factory

Insulation Resistance Test
Turns Ratio Test
Winding Resistance Test
No Load Loss Test
Load Loss Test
High Voltage Test
Induced Voltage Test
Oil BDV Test
Polarity Test
Leakage Test
Temperature Rise Test (If Required)
Routine Tests as per IS 2026

Only transformers that pass every inspection are cleared for dispatch, with complete routine test reports supplied alongside each unit.


Common questions

FAQ

What is a 10 MVA transformer used for? +
A 10 MVA Distribution Transformer is designed for supplying reliable electrical power to utility substations, heavy industries, infrastructure projects, renewable energy plants, and large commercial facilities requiring high-capacity power distribution.
Is copper winding available? +
Yes — the transformer can be supplied with either copper or aluminium windings based on customer specifications and application requirements.
Which cooling system is used? +
The standard cooling system is ONAN (Oil Natural Air Natural), while ONAF (Oil Natural Air Forced) and OFAF (Oil Forced Air Forced) are available for higher-capacity or demanding operating conditions.
Can the transformer be customized? +
Yes — primary and secondary voltages, impedance, vector group, tap changer, winding material, cooling method, and other technical specifications can be customized to meet project requirements.
Which standards does it comply with? +
The transformer is manufactured and tested in accordance with IS 1180 and IS 2026 standards to ensure safety, quality, and reliable performance.
Do you provide routine test reports? +
Yes — every 10 MVA Distribution Transformer is supplied with comprehensive routine test reports and quality inspection documents before dispatch, ensuring compliance with applicable standards and dependable field performance.

Get Started Today

Powering Industries with Reliable Transformer Solutions
Get in touch with our experts for transformer manufacturing, customization, repair, testing, and installation services.

Have Additional Questions?

Need help choosing the right transformer for your project? Our team is here to assist you with technical guidance and quotations.