Power Transformer Manufacturing 2 MVA

ISO 9001:2015 certified manufacturer of power transformers from 2 MVA, built to IS standards for maximum reliability and operational efficiency.

2 MVA Distribution Transformer — Shri Ram Transformer
How it works

Stepping high voltage down to usable power

Engineered for medium and large-scale industrial, commercial, and utility applications, the transformer steps medium-voltage electricity down to a safe, stable low voltage — using electromagnetic induction between three-phase primary and secondary windings, with no moving parts.

HV INPUT → CORE & WINDINGS → LV OUTPUT
High voltage (input) Winding / core Low voltage (output)

The primary (HV) winding has many turns of fine wire; the secondary (LV) winding has fewer turns of thicker wire. Electrical energy crosses between them magnetically through the CRGO core — the ratio of turns sets the ratio of voltages, with the two circuits fully isolated from each other.


Built for the field

What goes into every unit

Each transformer is engineered for low losses, high short-circuit strength, and long, low-maintenance operation under demanding industrial and utility conditions.

Premium CRGO Core

Cold Rolled Grain Oriented silicon steel keeps core and copper losses low while improving magnetic performance.

Copper or Aluminium Winding

Choose electrolytic-grade copper or high-conductivity aluminium windings, both built for long service life.

Heavy-Duty Welded Tank

Corrosion-resistant, welded steel tank built for high short-circuit strength and continuous operation.

ONAN Cooling with ONAF Option

Standard Oil Natural Air Natural cooling, with Oil Natural Air Forced available for higher thermal loads.

Excellent Voltage Regulation

Holds a consistent output voltage through load fluctuations, protecting connected equipment.

Low Maintenance Design

Built for long operational life with minimal upkeep, routine tested per IS 2026 before dispatch.


Nameplate data

Technical specifications

Standard configuration below — voltage ratio, tap changer, vector group, and winding material can be customized to your project.

Shri Ram Transformer — Type DT-2000
Rating2 MVA (2000 kVA)
PhaseThree Phase
Frequency50 Hz
CoolingONAN / ONAF (Optional)
Core MaterialCRGO Silicon Steel
WindingCopper / Aluminium
InsulationOil Immersed
InstallationOutdoor
StandardIS 1180 / IS 2026
Tap ChangerOCTC / OLTC (Optional)
Primary Voltage11 / 22 / 33 kV
Secondary Voltage433 V or As Required
Vector GroupDyn11
ImpedanceAs Per IS Standards

Where it's installed

Applications

Sized for medium and large-scale industrial, commercial, and utility loads where a stable, high-capacity supply matters most.

Manufacturing Plants
Industrial Estates
Commercial Buildings
Hospitals
Shopping Malls
Data Centers
Infrastructure Projects
Utility Power Distribution
Renewable Energy Plants
Large Residential Townships

From design to dispatch

Manufacturing process

Every unit moves through the same monitored sequence, start to finish.

01

Engineering & Design

Specifications finalized against project requirements.

02

CRGO Core Cutting & Assembly

CRGO steel cut and assembled to spec.

03

Coil Winding & Insulation

Primary and secondary windings formed and insulated.

04

Tank Fabrication & Core-Coil Assembly

Heavy-duty welded steel tank built and core-coil assembly fitted.

05

Vacuum Drying & Oil Filling

Assembly dried under vacuum, then filled with insulating oil.

06

Routine Testing & Quality Inspection

Full IS 2026 test sequence and final quality inspection.

07

Packing & Safe Dispatch

Secure packaging and dispatch with test documentation.


Quality assurance

Every unit is tested before it leaves the factory

Insulation Resistance Test
Turns Ratio Test
Winding Resistance Test
No Load Loss Test
Load Loss Test
High Voltage Test
Induced Voltage Test
Oil BDV Test
Polarity Test
Leakage Test
Temperature Rise Test (If Required)
Routine Tests as per IS 2026

Only transformers that pass every inspection are cleared for dispatch, with complete routine test reports supplied alongside each unit.


Common questions

FAQ

What is a 2 MVA transformer used for? +
A 2 MVA transformer is commonly used for industrial plants, commercial facilities, utility substations, hospitals, data centers, and infrastructure projects requiring reliable power distribution.
Is copper winding available? +
Yes — both copper and aluminium winding options are available according to customer requirements.
Which cooling method is used? +
The standard cooling system is ONAN, while ONAF cooling is available for higher load applications.
Can the transformer be customized? +
Yes — voltage ratio, impedance, vector group, tap changer, cooling method, and winding material can all be customized.
Which standards does it comply with? +
The transformer is manufactured and tested in accordance with IS 1180 and IS 2026 standards.
Do you provide routine test reports? +
Yes — every 2 MVA transformer is supplied with complete routine test reports before dispatch to ensure quality and performance.

Get Started Today

Powering Industries with Reliable Transformer Solutions